Universidad San Sebastián  
 

Repositorio Institucional Universidad San Sebastián

Búsqueda avanzada

Descubre información por...

 

Título

Ver títulos
 

Autor

Ver autores
 

Tipo

Ver tipos
 

Materia

Ver materias

Buscar documentos por...




Mostrar el registro sencillo del ítem

dc.contributor.author Balzer, Kristian
dc.contributor.author López-Portilla, Bárbaro M.
dc.contributor.author Toledo, Felipe
dc.contributor.author Hoffer, Alvaro
dc.contributor.author Lazo, Joaquín
dc.contributor.author Iglesias Martínez, Miguel E.
dc.date.accessioned 2026-02-08T03:36:32Z
dc.date.available 2026-02-08T03:36:32Z
dc.date.issued 2025-10
dc.identifier.issn 2076-3417
dc.identifier.other Mendeley: 69633582-1c77-3d73-a2a7-a1cd3c3b2640
dc.identifier.uri https://repositorio.uss.cl/handle/uss/20816
dc.description Publisher Copyright: © 2025 by the authors.
dc.description.abstract Chile’s National Electric System is one of the countries in South America with the greatest potential for the development of solar–wind generation, allowing for the acceleration of the energy transition with the definitive withdrawal of conventional fossil fuel thermal generation. However, the integration of the market of ancillary services requires security, stability, and quality of service to the electricity system. In this context, the primary frequency control (PFC) is considered as the first line of defense of an electric power system, due to its immediate action in severe frequency variations when they exceed ±0.7 Hz with respect to the nominal operating frequency of 50.00 Hz, allowing the safe and efficient integration of large blocks of solar–wind renewable generation in spite of the uncertainty or forecast errors that could cause its massive dispatch. The principal contribution of this work is the implementation of a technical-economic mathematical model that minimizes the total costs of real-time power reserve reallocations for primary frequency control, using the dynamic factors of stationarity in those conventional and renewable solar–wind generation plants. The validation of the model is consolidated through real scenarios, specifically the deficit of power reserves, which necessitates a dynamic response in primary frequency control over 10 s and 5 min. In terms of expected results, the proposed model contributes to the Supra-/Infra-Marginal methodology, reducing the total costs of power reallocation reserves for primary frequency control, compared to other inefficient methods, such as the Maximum Power Method, the Minimum Technical Method, and the Random Direct Instruction Method. en
dc.language.iso eng
dc.relation.ispartof vol. 15 Issue: no. 20 Pages:
dc.source Applied Sciences (Switzerland)
dc.title Technical-Economic Model in the Real-Time Ancillary Services Market for the Reallocation of Power Reserves in Primary Frequency Control en
dc.type Artículo
dc.identifier.doi 10.3390/app152011148
dc.publisher.department Facultad de Ingeniería


Ficheros en el ítem

Ficheros Tamaño Formato Ver

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem